Category: Wired alarm systems
Published: Thursday, 03 December 2015
Wired alarm system in a block of flats
|
Assumptions for the project:
Project goals:
- Zone I - Apartment No. 1 (ground floor): motion detectors - 1 pc, opening detectors - 1 pc
- Zona II - Apartment No. 2 (ground floor): motion detectors - 1 pc, opening detectors - 1 pc
- Zone III - Apartment No. 3 (first floor): motion detectors - 1 pc, opening detectors - 1 pc
- Zone IV - Apartment No. 4 (first floor): motion detectors - 1 pc, the detector opening - 1 pc
- Zone V - Apartment No. 5 (second floor): motion detectors - 1 pc, opening detectors - 1 pc
- Zone VI - Apartment No. 6 (second floor): motion detectors - 1 pc, opening detectors - 1 pc
- Zone VII - Apartment No. 7 (third floor): motion detectors - 1 pc, opening detectors - 1 pc
- Zone VIII - Apartment No. 8 (third floor): motion detectors - 1 pc, opening detectors - 1 pc
- motion detectors: wireless
- opening detectors: wired
Control:
- alarm switchboard CA64:
- 8 independent zones (one for each flat)
- switchboard casing
- keypads: LCD - 1 pc
- power supply: power supply with backup power
Alarm indication:
- External siren with independent power supply 120 dB
- Internal siren 105 dB
Alarm notification:
- transmission of alarm information via a phone line
Monitoring (option):
- transmission of alarm information to a monitoring station via a phone line
System handling:
- Independent passwords for 33 users with various access rights
- 8 - 96 lines, 8 independent zones
- separate telephone numbers for each zone notification
- Independent delays of entering / leaving for each zone (apartment)
Self-diagnostics:
- automatic control of operation of the alarm system, including a failure detection
Other functions:
- answering the phone and informing about the state of the system
- remote servicing of the system using computer with a modem
- possibility of remote control of locks, lighting and other equipment from the keypads
- able to initiate alarms PANIC, FIRE and HELP from a keypad
- memory of the last 255 events storing information about turning on/off the system, alarms, troubles, etc. with the date and time of occurrence and the user's identification number
- various variants of system arming:
- with automatic lock
- with lock in case of lack of leaving the building
Hits: 12650